Document Number:
NL EN 1504 2 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This Part of prEN 1504 specifies requirements for the identification, performance (including durability aspects), safety and evaluation of conformity of products and systems to be used for surface protection of concrete, to increase the durability of concrete and reinforced concrete structures, as well as for new concrete and for maintenance and repair work. The surface protective methods covered by this standard are the following: - hydrophobic impregnation; - impregnation; - coating. Flooring systems in buildings which are not intended to protect or reinstate the integrity of a concrete structure are standardised in EN 13813. When products and systems complying with this standard are used in flooring applications that involve substantial mechanical loading , they should also satisfy the requirements of EN 13813.
Document Number:
NL EN 1504 3 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies requirements for the identification, performance (including durability) and safety of products and systems to be used for the structural and non-structural repair of concrete structures. This European Standard covers repair mortars and concretes, possibly used in conjunction with other products and systems, to restore and/or to replace defective concrete and to protect reinforcement, necessary to extend the service life of a concrete structure exhibiting deterioration. The fields of application covered are in accordance with ENV 1504-9.
Document Number:
NL EN 1504 4 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This Part 4 of EN 1504 specifies requirements for the identification, performance (including durability) and safety of structural bonding products and systems to be used for the structural bonding of strengthening materials to an existing concrete structure, including: 1) The bonding of external plates of steel or other suitable materials (e.g. fibre reinforced composites) to the surface of a concrete structure for strengthening purposes, including the laminating of plates in such applications. 2) The bonding of hardened concrete to hardened concrete, typically associated with the use of precast units in repair and strengthening. 3) The casting of fresh concrete to hardened concrete using an adhesive bonded joint where it forms a part of the structure and is required to act compositely. The performance requirements in this Part of this Standard may not be applicable to highly specialised applications in extreme environmental conditions, e.g. cryogenic use, nor do they cover specialised circumstances such as accidental impact, e.g. due to traffic or ice, or earthquake loading where specific performance requirements will apply.
Document Number:
NL EN 1504 5 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies requirements and conformity criteria for the identification, performance (including durability aspects) and safety of injection products for the repair and protection of concrete structures, used for: - force transmitting filling of cracks, voids and interstices in concrete (category F, see 3.1); - ductile filling of cracks, voids and interstices in concrete (category D, see 3.1); - swelling fitted filling of cracks, voids and interstices in concrete (category S, see 3.1). The performance requirements in this part of this document may not be applicable to highly specialised applications in extreme environmental conditions, e.g. cryogenic use, nor do they cover specialised circumstances such as accidental impact, e.g. due to traffic or ice, or earthquake loading, where specific performance requirements will apply. This European Standard does not cover: - the treatment of cracks by widening them and sealing them with an elastomeric sealing compound; - external filling of cavities, that is, the placement of product outside the structure (generally within the surrounding foundation soils, or at the interface between the structure and the soil); this is covered by EN 12715, under contact grouting; - preliminary injection works, if necessary, to temporarily stop water passage during waterproofing injection.
Document Number:
NL EN 1504 6 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This Part of EN 1504 specifies requirements for the identification, performance (including durability) and safety of products and systems to be used for the anchoring of reinforcing steel (rebar) as used for structural strengthening to ensure the continuity of reinforced concrete structures. This Part of EN 1504 covers the fields of application in accordance with repair method 4.2 of ENV 1504-9:1997. NOTE It is assumed that a proper structural assessment of the structural elements to be subjected to repair is carried out by qualified engineers and that the choice of the products and systems to be used as well as the design are based on this assessment.
Document Number:
NL EN 14695 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies characteristics and performance of reinforced bitumen sheets for waterproofing of concrete bridge decks and other trafficked areas of concrete where the waterproofing system is bonded to the concrete deck and overlaid by asphalt. The standard also specifies the test methods used for verifying the characteristics and performance.
Document Number:
NL EN 1656 : 2016
Sector:
Chemical Technology
Status:
C
Production Year:
2016
Price:
35000.0000
This document specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less, as some dilution is always produced by adding the test organisms and interfering substance. The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used. This document applies to products that are used for equipment disinfection by immersion, surface disinfection by wiping, spraying, flooding or other means and teat disinfection in the veterinary area - e.g. in the breeding, husbandry, production, veterinary care facilities, transport and disposal of all animals except when in the food chain following death and entry into processing industry. This document also applies to products used for teat disinfection in these veterinary areas. This method is not applicable to evaluate the activity of hand hygiene products. For these products reference is made to EN 14885, which specifies in detail the relationship of the various tests to one another and to "use recommendations". NOTE This method corresponds to a phase 2 step 1 test.
Document Number:
NL EN 14204 : 2016
Sector:
Chemical Technology
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies a test method and the minimum requirements for mycobactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use-products - with water. Products can only be tested at a concentration of 80 % or less, as some dilution is always produced by adding the test organisms and interfering substance. This European Standard applies to products that are used in the veterinary area - i.e. in the breeding, husbandry, production, transport and disposal of all animals except when in the food chain following death and entry to the processing industry. EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations". NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used. NOTE 2 This method corresponds to a phase 2 step 1 test.
Document Number:
NL EN 14349 : 2016
Sector:
Chemical Technology
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water, or - in the case of ready-to-use-products - with water. This European Standard applies to products that are used in the veterinary area on non-porous surfaces without mechanical action i.e. in the breeding, husbandry, production, transport and disposal of all animals except when in the food chain following death and entry to the processing industry. EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations". NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used. NOTE 2 This method corresponds to a Phase 2 Step 2 test. NOTE 3 This method cannot be used to evaluate the activity of products against mycobacteria.
Document Number:
NL EN 14675 : 2016
Sector:
Chemical Technology
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use-products - with water. Products can only be tested at a concentration of 80 % or less as some dilution is always produced by adding the test organisms and interfering substance. This European Standard applies to products that are used in the veterinary area, i.e. in the breeding, husbandry, production, transport and disposal of all animals except when in the food chain following death and entry to the processing industry. NOTE 1 The method described is intended to determine the virucidal activity of commercial formulations or active substances under the conditions in which they are used. NOTE 2 This method corresponds to a phase 2 step 1.
Document Number:
NL EN 13251 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies the relevant characteristics of geotextiles and geotextile-related products used in the construction of earthworks, foundations and retaining structures, and the appropriate test methods to determine these characteristics. The intended use of these geotextiles or geotextile-related products is to fulfil one or more of the following functions: filtration, separation, and reinforcement. The separation function will always occur in conjunction with filtration or reinforcement, and hence will not be specified alone. This European Standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318 1. This European Standard provides for the assessment and verification of constancy of performance of the product to this European Standard and for factory production control procedures. Particular application cases may contain requirements regarding additional properties and – preferably standardized – test methods, if they are technically relevant. This European Standard may be used to derive design values by taking into account factors within the context of the definitions given in EN 1997 1 (Eurocode 7), e.g. factors of safety. The design life of the product should be determined, since its function may be temporary, as a construction expediency, or permanent, for the lifetime of the structure.
Document Number:
NL EN 13252 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies the relevant characteristics of geotextiles and geotextile-related products used in drainage systems and the appropriate test methods to determine these characteristics. The intended use of these geotextiles or geotextile-related products is to fulfil one or more of the following functions: filtration, separation and drainage. The separation function is always used in conjunction with filtration or drainage. Accordingly, separation will never be specified alone. This European Standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318 1. This European Standard provides for the assessment and verification of constancy of performance of the product to this European Standard and for factory production control procedures. This European Standard defines requirements to be met by manufacturers and distributors with regard to the presentation of product properties. Particular application cases may contain requirements regarding additional properties and – preferably standardized – test methods, if they are technically relevant. This European Standard may be used to derive design values by taking into account factors within the context of the definitions given in EN 1997 1 (Eurocode 7), e.g. factors of safety. The design life of the product should be determined, since its function may be temporary, as a construction expediency, or permanent, for the lifetime of the structure.
Document Number:
NL EN 13253 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies the relevant characteristics of geotextiles and geotextile-related products used in erosion control works for preventing the migration of fine-graded material into layers of coarser material due to alternating hydraulic gradients, and the appropriate test methods to determine these characteristics. This European Standard covers applications in coastal protection and bank revetment. This European Standard does not cover surface erosion, where the geotextile or geotextile-related product is located at the surface. The intended use of these geotextiles or geotextile-related products is to fulfil one or more of the following functions: filtration, separation, and reinforcement. The separation function will always occur in conjunction with filtration or reinforcement, and hence will not be specified alone. This European Standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318 1. This European Standard provides for the assessment and verification of constancy of performance of the product to this European Standard and for factory production control procedures. Particular application cases may contain requirements regarding additional properties and – preferably standardized – test methods, if they are technically relevant. This European Standard may be used to derive design values by taking into account factors within the context of the definitions given in EN 1997 1 (Eurocode 7), e.g. factors of safety. The design life of the product should be determined, since its function may be temporary, as a construction expediency, or permanent, for the lifetime of the structure. Particular application cases may contain requirements regarding additional properties and - preferably standardized - test methods, if they are technically relevant. This European Standard may be used to derive design values by taking into account factors within the context of the definitions given in EN 1997-1 (Eurocode 7), e.g. factors of safety. The design life of the product should be determined, since its function may be temporary, as a construction expediency, or permanent, for the lifetime of the structure.
Document Number:
NL EN 13257 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies the relevant characteristics of geotextiles and geotextile-related products used in solid waste disposals, and the appropriate test methods to determine these characteristics. The intended use of these geotextiles or geotextile-related products is to fulfil one or more of the following functions: filtration, separation, reinforcement and protection. The separation function will always occur in conjunction with filtration or reinforcement, and hence will not be specified alone. This European Standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318 1. This European Standard provides for the assessment and verification of constancy of performance of the product to this European Standard and for factory production control procedures. Particular application cases may contain requirements regarding additional properties and – preferably standardized – test methods, if they are technically relevant. This European Standard may be used to derive design values by taking into account factors within the context of the definitions given in EN 1997 1 (Eurocode 7), e.g. factors of safety. The design life of the product should be determined, since its function may be temporary, as a construction expediency, or permanent, for the lifetime of the structure.
Document Number:
NL EN 13265 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies the relevant characteristics of geotextiles and geotextile-related products used in liquid waste containment projects, and the appropriate test methods to determine these characteristics. The intended use of these geotextiles or geotextile-related products is to fulfil one or more of the following functions: filtration, reinforcement and protection. This European Standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318 1. This European Standard provides for the assessment and verification of constancy of performance of the product to this European Standard and for factory production control procedures. Particular application cases may contain requirements regarding additional properties and – preferably standardized – test methods, if they are technically relevant. This European Standard may be used to derive design values by taking into account factors within the context of the definitions given in EN 1997 1 (Eurocode 7), e.g. factors of safety. The design life of the product should be determined, since its function may be temporary, as a construction expediency, or permanent, for the lifetime of the structure.
Document Number:
NL EN 13492 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies the characteristics of geosynthetic barriers, including polymeric geosynthetic barriers, clay geosynthetic barriers and bituminous geosynthetic barriers, when used as fluid barriers and separation layer in the construction of liquid waste disposal sites, and in the construction of transfer stations or secondary containment for the storage of liquid waste on a waste disposal site only and the appropriate test methods to determine these characteristics. The intended use of these products is to control the leakage of fluids through the construction. This European Standard is not applicable to geotextiles or geotextile-related products as defined in EN ISO 10318-1. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard including factory production control procedures. This European Standard defines characteristics to be considered with regard to the presentation of perfo
Document Number:
NL EN 13493 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies the characteristics of geosynthetic barriers, including polymeric geosynthetic barriers, clay geosynthetic barriers and bituminous geosynthetic barriers, when used as fluid barriers and separation layer in the construction of solid waste storage and disposal sites, and the appropriate test methods to determine these characteristics. The intended use of these products is to control the leakage of fluids through the construction. This European Standard is not applicable to geotextiles or geotextile-related products as defined in EN ISO 10318-1. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard including factory production control procedures. This European Standard defines characteristics to be considered with regard to the presentation of performance. NOTE Where potable water is or can be in direct contact with the product, other relevant standards, requirements
Document Number:
NL EN 15381 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies the relevant characteristics of metallic and non-metallic geotextiles and geotextile-related products used in the construction of pavements and asphalt overlays and the appropriate test methods to determine these characteristics. The intended use of these geotextiles and geotextile-related products is to fulfil one or more of the following functions: reinforcement, stress relief and barrier. The use of geotextiles and geotextile-related products is to be considered as a part of an interlayer and asphalt overlay system. This standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318. This standard provides for evaluation of conformity of the product to this European Standard and for factory production control procedures. This standard defines requirements to be met by manufacturers and distributors with regard to the presentation of product properties. NOTE 1 Particular application cases or national specifications may contain additio
Document Number:
NL EN 15382 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies the relevant characteristics of geosynthetic barriers (polymeric, clay and bituminous geosynthetic barriers), used as fluid barriers in infrastructure works, e.g. roads, railroads, runways of airports, and the appropriate test methods to determine these characteristics. Tunnels and underground structures are addressed in EN 13491. The intended use of these products is to control the pathway of liquids through the construction and to limit any contamination, e.g. by de-icing products, of groundwater or water sources. This European Standard is applicable to geosynthetic barriers, but not to geotextiles or geotextile-related products, as defined in EN ISO 10318. This European Standard provides for the evaluation of conformity of the product to this European Standard. This European Standard defines requirements to be met by manufacturers and their authorised representatives with regard to the presentation of product properties. This European Standard does n
Document Number:
NL EN 1504 7 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
25000.0000
This Part of EN 1504 specifies requirements for the identification and the performance (including durability aspects) of products and systems for active and barrier coatings for protection of existing uncoated steel reinforcement and embedded steel in concrete structures under repair. This standard does not cover products for corrosion protection of pre-stressing steels and stainless steels.
Document Number:
NL EN 1504 9 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard specifies the characteristics of geosynthetic barriers, including polymeric geosynthetic barriers, clay geosynthetic barriers and bituminous geosynthetic barriers, when used as fluid barriers and separation layer in the construction of solid waste storage and disposal sites, and the appropriate test methods to determine these characteristics. The intended use of these products is to control the leakage of fluids through the construction. This European Standard is not applicable to geotextiles or geotextile-related products as defined in EN ISO 10318-1. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard including factory production control procedures. This European Standard defines characteristics to be considered with regard to the presentation of performance. NOTE Where potable water is or can be in direct contact with the product, other relevant standards, requirements and/or regulations can be considered for the design. This European Standard specifies the relevant characteristics of metallic and non-metallic geotextiles and geotextile-related products used in the construction of pavements and asphalt overlays and the appropriate test methods to determine these characteristics. The intended use of these geotextiles and geotextile-related products is to fulfil one or more of the following functions: reinforcement, stress relief and barrier. The use of geotextiles and geotextile-related products is to be considered as a part of an interlayer and asphalt overlay system. This standard is not applicable to geosynthetic barriers, as defined in EN ISO 10318. This standard provides for evaluation of conformity of the product to this European Standard and for factory production control procedures. This standard defines requirements to be met by manufacturers and distributors with regard to the presentation of product properties. NOTE 1 Particular application cases or national specifications may contain additional requirements regarding product application or installation and specifying preferably standardized test methods, if they are technically relevant and not conflicting with European Standards. "This European Standard specifies the relevant characteristics of geosynthetic barriers (polymeric, clay and bituminous geosynthetic barriers), used as fluid barriers in infrastructure works, e.g. roads, railroads, runways of airports, and the appropriate test methods to determine these characteristics. Tunnels and underground structures are addressed in EN 13491. The intended use of these products is to control the pathway of liquids through the construction and to limit any contamination, e.g. by de-icing products, of groundwater or water sources. This European Standard is applicable to geosynthetic barriers, but not to geotextiles or geotextile-related products, as defined in EN ISO 10318. This European Standard provides for the evaluation of conformity of the product to this European Standard. This European Standard defines requirements to be met by manufacturers and their authorised representatives with regard to the presentation of product properties. This European Standard does not cover applications where the geosynthetic barrier will be in contact with water that has been treated for human consumption. In these cases other relevant standards, requirements and/or regulations should be observed." This Part of EN 1504 specifies requirements for the identification and the performance (including durability aspects) of products and systems for active and barrier coatings for protection of existing uncoated steel reinforcement and embedded steel in concrete structures under repair. This standard does not cover products for corrosion protection of pre-stressing steels and stainless steels." This Part of EN 1504 specifies procedures for sampling, quality control, assessment and verification of the constancy of performance (AVCP) including marking and labelling of products and systems for the protection and repair of concrete according to EN 1504 2 to EN 1504-7. " This Part of EN 1504 sets out basic considerations for specification of protection and repair of reinforced and unreinforced concrete structures (including, for example, pavements, runways, floor slabs and pre-stressed structures) using products and systems specified in other Parts of the EN 1504 series or any other relevant European Standard or European Technical Approval. This European Standard covers atmospherically exposed, buried and submerged structures. This European Standard includes: a) the need for inspection, testing and assessment before and after repair; b) protection from causes of defects and their repair in concrete structures. Causes of such defects may include: 1) mechanical actions, e.g. impact, overloading, movement caused by settlement, blast, vibration and seismic actions; 2) chemical and biological actions from environments, e.g. sulphate attack, alkali aggregate reaction; 3) physical actions, e.g. freeze-thaw, thermal cracking, moisture movement, salt crystallisation and erosion; 4) fire damage; 5) reinforcement corrosion resulting from: i) physical loss of the protective concrete cover; ii) chemical loss of alkalinity in the protective concrete cover as a result of reaction with atmospheric carbon dioxide (carbonation); iii) chloride (or other chemical) contamination of the concrete; iv) stray electrical currents conducted or induced in the reinforcement from neighbouring electrical installations. c) repair of defects caused by inadequate design, specification or construction or use of unsuitable construction materials; d) providing the required structural capacity by: 1) replacement or addition of embedded or external reinforcement; 2) filling of cracks and voids within or between elements to ensure structural continuity; 3) replacement or addition of concrete or whole elements; e) waterproofing as an integral part of protection and repair.
Document Number:
NL EN 1504 10 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This part of EN 1504 gives requirements for: - substrate condition before and during application of systems and products; - storage of systems and products; - structural stability during preparation, protection and repair; - methods of protection and repair; - quality control for execution of work; - maintenance of the structure.
Document Number:
NL EN 13369 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This document specifies the requirements, the basic performance criteria and the Assessment and Verification of Constancy of Performance (AVCP) for unreinforced, reinforced and prestressed precast concrete products made of compact light-, normal- and heavyweight concrete according to EN 206 with no appreciable amount of entrapped air other than entrained air. Concrete containing fibres for other than mechanical properties (steel, polymer or other fibres) is also covered. It does not cover prefabricated reinforced components of lightweight aggregate concrete with open structure. It may also be used to specify products for which there is no standard. Not all of the requirements (Clause 4) of this standard are relevant to all precast concrete products. If a specific product standard exists, it takes precedence over this document. The precast concrete products dealt with in this standard are factory produced for building and civil engineering works. This document can also be applied to products manufactured in temporary plants on site if the production is protected against adverse weather conditions and controlled following Clause 6 provisions. The analysis and design of precast concrete products is not within the scope of this document but it does offer, for non-seismic zones, information about: - the choice of partial safety factors defined by the pertinent Eurocode; - the definition of some requirements for prestressed concrete products.
Document Number:
NL EN 1168 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
TThis European Standard deals with the requirements and the basic performance criteria and specifies minimum values where appropriate for precast hollow core slabs made of prestressed or reinforced normal weight concrete according to EN 1992-1-1:2004. This European Standard covers terminology, performance criteria, tolerances, relevant physical properties, special test methods, and special aspects of transport and erection. Hollow core elements are used in floors, roofs, walls and similar applications. In this European Standard the material properties and other requirements for floors and roofs are dealt with; for special use in walls and other applications, see the relevant product standards for possible additional requirements. The elements have lateral edges with a grooved profile in order to make a shear key to transfer shear through joints contiguous elements. For diaphragm action the joints have to function as horizontal shear joints. To improve this action vertical grooves may be provided. The elements are manufactured in factories by extrusion, slipforming or mouldcasting. Fitting slabs (narrowed slab elements) and recesses to the hollow core slabs can be made during production or afterwards. Hollow core slabs can have provisions for thermal activation, heating, cooling, sound insulation, etc. Due to these provisions, the concrete temperature remains in it’s natural range. This European Standard also deals with solid slab elements used in conjunction with hollow core slabs and manufactured by extrusion, slipforming or mouldcasting, equivalent to the manufacturing of hollow core slabs. These solid slabs have the same overall cross-section as hollow core slabs, however without hollow cores. The application of the standard is limited for prestressed elements to a maximum depth of 500 mm and for reinforced elements to a maximum depth of 300 mm. For both types, the maximum width without transverse reinforcement is limited to 1 200 mm and with transverse reinforcement to 2 400 mm. The elements may be used in composite action with an in situ structural topping cast on site. The applications considered are floors and roofs of buildings, including areas for vehicles in the category F and G of EN 1991-1-1 which are not subjected to fatigue loading. For building in seismic zones additional provisions are given in EN 1998-1. This European Standard does not deal with complementary matters. E.g. the slabs should not be used in roofs without additional protection against water penetration.
Document Number:
NL EN 13224 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This document identifies the requirements, the basic performance criteria and evaluation of conformity for precast ribbed elements made of reinforced or prestressed normal weight concrete, used in floors or roofs. The elements consist of a top and/or bottom slab and one or more (usually two) ribs; transverse ribs may also be present. Some examples of precast elements considered in this document are shown in Annex A. Specific requirements for minor floor elements are listed in Annex B. This document covers terminology, performance criteria, tolerances, relevant physical properties, test methods and aspects of transport and erection. This document does not cover load-bearing capacity determined by testing.
Document Number:
NL EN 13225 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard identifies the requirements, the basic performance criteria and evaluation of conformity for precast linear elements (such as columns, beams and frame elements) made of reinforced or prestressed normal or lightweight concrete, used for the construction of the structures of buildings and other civil engineering works, except bridges. This document covers terminology, performance criteria, tolerances, relevant physical properties, test methods, and aspects of transport and erection. This document does not cover load bearing capacity determined by testing. This standard does not cover lintels with length up to 4,5 m used in masonry walls
Document Number:
NL EN 15037 3 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard deals with the requirements and the basic performance criteria for blocks made in clay, used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor and roof systems. Examples of typology of floor and roof systems are given in Annex B of EN 15037-1:2008.
Document Number:
NL EN 15037 4 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard deals with the requirements and the basic performance criteria for blocks made in expanded polystyrene (EPS), used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor systems. EPS block may be totally made in EPS or combined with different materials such as plaster or wood wool. If EPS is combined with other materials, these materials should not contribute to more than 50 % of the mechanical resistance of the block. If not, the block is covered by EN 15037-5, Precast concrete products - Beam-and-block floor systems - Part 5: Lightweight blocks for simple formwork. Examples of typology of floor systems are given in Annex B of EN 15037-1:2008.
Document Number:
NL EN 14843 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This standard gives specifications for materials, production, properties, requirements and methods of testing for precast concrete monolithic stairs, and for precast concrete elements (e.g. individual steps) used to make reinforced and/or prestressed concrete stairs. This standard is applicable to structural stairs for indoor or outdoor use. This standard covers precast concrete stairs and associated landings of monolithic design or constructed from individual steps supported by beams or columns. Supporting elements may include in situ concrete. This standard covers terminology, performance criteria, verification methods, tolerances, relevant physical properties, special test methods and specific aspects of transport, erection and connection. Geometrical properties related to functionality of stairs are not covered by this standard and can be found in National regulations or local practice. Precast concrete stairs are classified into two main product families : monolithic stairs constructed from precast concrete components consisting of flights, landings or a combination of these. They may include vertical supporting elements ; stairs constructed from individual steps, whether load bearing or not, assembled on site with, for example, carriages or a central column. Their shape may be straight or winding. Stairs may incorporate parapets (on one or both sides) and landings. Stairs may have simple bearings (e.g. on corbels, walls or beams), bolted connections or they may be connected with reinforcement and in situ concrete. The surfaces of the precast elements may be exposed or covered by finishes.
Document Number:
NL EN 14991 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard deals with the requirements and the basic performance criteria and specifies where applicable minimum values for precast foundation elements (comprising columns with integrated foundation elements, pocket foundation elements, sockets) made of reinforced normal weight concrete for structure of buildings according to EN 1992-1-1. This European Standard covers terminology, performance criteria, tolerances, relevant physical properties and special aspects of transport and erection. This European Standard does not cover the bearing capacity determined by testing.
Document Number:
NL EN 15258 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard deals with the requirements, the basic performance criteria and evaluation of conformity for precast elements made of plain, reinforced or prestressed normal weight concrete, used for the construction of retaining walls. The products covered by this European Standard are intended to be used as part of retaining walls in applications such as: - to retain natural ground excavations and trenches; - to retain earth fills for roads, platforms, etc.; - in bridge abutments and their flank walls; - to retain several kinds of loose materials such as sand, gravel, etc. Some examples of precast elements considered in this European Standard are shown in the Informative Annex B. The products may be used in seismic areas on condition that they fulfil the requirements specific to this use. This European Standard does not cover: - products for retaining walls of tanks or reservoirs of liquids; - retaining wall elements up to a height of 1,0 m and those assembled to form retainin
Document Number:
NL EN 12794 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This document specifies the terminology, requirements, basic performance criteria, test methods and evaluation of conformity that will be applied to precast concrete foundation piles, factory produced for building and civil engineering works and installed at the site by the use of impact, vibration, pressing or other suitable techniques. This document may also be applied to products manufactured in temporary plants on site where production is controlled in accordance with the provisions of Clause 6 and is protected against adverse weather conditions as necessary. This document applies to foundation piles produced in a plant as reinforced or prestressed concrete elements. The cross-section may be solid or provided with a hollow core, either prismatic or cylindrical. The cross-section may be constant over the full length or tapered partly or wholly along the pile or pile segment length. This document deals with foundation piles manufactured either in one length or in segments with cast-in pile joints. The foundation piles may have an enlarged toe or a pile shoe. This document applies to normal weight concrete as defined in EN 206-1 compacted so as to retain no appreciable amount of entrapped air other than entrained air.
Document Number:
NL EN 12843 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This Standard specifies requirements for precast concrete poles (also commonly called masts) (either all of a piece or composed of elements), reinforced and/or prestressed as structural elements; they may be hollow or solid and may receive or include additional components (e.g. cross-arms, platforms etc.), inserts and connectors. Additional elements may be connected to pole elements. Structures made from such elements in mono- or multi-legged form may be used for : - overhead electrical lines ; - telecommunication lines ; - overhead electrical lines for railways, trams and similar ; - supports for lighting ; - supports for loudspeaker installation ; - antenna and telecommunication poles ; - supports for wind turbines ; - and similar installations. This Standard does not cover lighting columns for use in traffic circulation areas.
Document Number:
NL EN 124 1 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard is applicable to manhole tops and gully tops with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers installed in areas subjected to pedestrian and/or vehicular traffic. It specifies definitions, classification, general principles of design, performance requirements and test methods for gully tops and manhole tops according to: - EN 124 2, for gully tops and manhole tops made of cast iron; - EN 124 3, for gully tops and manhole tops made of steel or aluminium alloy; - EN 124 4, for gully tops and manhole tops made of steel reinforced concrete; - EN 124 5, for gully tops and manhole tops made of composite materials; - EN 124 6, for gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U). Part 1 is only applicable in combination with at least one of the standards EN 124 2, EN 124 3, EN 124 4, EN 124 5 and EN 124 6 each of which has this Part 1 as an integral part. This European Standard is not applicable to: - gratings/covers as part of prefabricated drainage channels according to EN 1433, - floor and roof gullies in buildings which are specified in EN 1253 1, - surface boxes
Document Number:
NL EN 124 2 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard is applicable to gully tops and manhole tops made of flake graphite cast iron and/or spheroidal graphite cast iron whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in: - areas which can only be used by pedestrians and pedal cyclists (at least class A 15), - pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), - the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250), - carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), - areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600), - areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900). This European Standard is not applicable in isolation but only in combination with EN 124 1 and gives guidance for combinations of covers/grating made from cast iron with frames according to EN 124 3, EN 124 4, EN 124 5 and EN 124 6. This European Standard is not applicable to: - fillings installed on site, e.g. concrete, paving blocks, etc., - concave gratings for classes D 400 installed in carriageways of roads and hard shoulders and concave gratings for classes F 900 and E 600, - gratings/covers as part of prefabricated drainage channels according to EN 1433, - floor and roof gullies in buildings which are specified in EN 1253 (all parts), - surface boxes.
Document Number:
NL EN 124 3 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard is applicable to gully tops and manhole tops made of mild steel, stainless steel and aluminium alloys whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation in areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in: - areas which can only be used by pedestrians and pedal cyclists (at least class A 15), - pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), - the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250), - carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), - areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600), - areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900). This European Standard is not applicable in isolation but only in combination with EN 124 1 and gives guidance for combinations of covers/gratings made from steel or aluminium alloys with frames according to EN 124 2 and EN 124 4, EN 124 5 and EN 124 6. Fabrication of manhole tops and gully tops in accordance with this standard is limited to cold forming, mechanical crimping or welding together component parts made from metal plate, strip or bar or rolled or extruded metal sections. This European Standard is not applicable to: - manhole tops and gully tops made of aluminium tread plates for use in carriageways of roads (class D 400) and areas imposing high wheel loads (Classes E 600 and F 900), - concave gratings for classes D 400 installed in carriageways of roads and hard shoulders and concave gratings for classes F 900 and E 600. - gratings/covers as part of prefabricated drainage channels according to EN 1433, - floor and roof gullies in buildings which are specified in EN 1253 (all parts), - surface boxes.
Document Number:
NL EN 124 4 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard is applicable to precast gully tops and manhole tops made of steel reinforced concrete with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in - areas which can only be used by pedestrians and pedal cyclists (at least class A 15), - pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), - the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250), - carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), - areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600), - areas imposing particul
Document Number:
NL EN 124 5 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This European Standard is applicable to precast gully tops and manhole tops made of steel reinforced concrete with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in - areas which can only be used by pedestrians and pedal cyclists (at least class A 15), - pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), - the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250), - carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), - areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600), - areas imposing particularly high wheel loads, e.g. aircraft pavements (Group 6, class F 900). This European Standard is not applicable in isolation but only in combination with EN 124 1 and gives guidance for combinations of covers/gratings made of steel reinforced concrete with frames according to EN 124 2, EN 124 3, EN 124 5 and EN 124 6. This European Standard is not applicable to: - concave gratings for class D 400 installed in carriageways of roads and hard shoulders and concave gratings for classes F 900 and E 600; - gratings/covers as part of prefabricated drainage channels according to EN 1433; - floor and roof gullies in buildings which are specified in EN 1253 (all parts); - surface boxes.
Document Number:
NL EN 14472 3 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
25000.0000
This Technical Specification provides recommendations for the installation of laminate floor coverings. Generally laminate floor coverings are installed as floating floors but in some applications they can be integrally glued to the subfloor. This Technical Specification only details suitable methods for floating floor installation and advises on the selection of the materials required for their implementation. The guidelines in this Technical Specification are intended for use in cases where manufacturer's instructions, taking account of the national code of practice in the country where the installation is to be made, are not available. References to the national codes that are currently available are listed in the bibliography of the various parts of this Technical Specification. This part 3 of the Technical Specification is intended for use in conjunction with part 1 that deals with general matters relevant to textile and resilient floor coverings as well as to laminate floor coverings. All parts of the Technical Specification are intended to supplement, and not conflict with, National Standards.
Document Number:
NL EN TS 14472 4 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
25000.0000
This Technical Specification provides recommendations for the installation of resilient floor coverings. It covers products composed of polyvinyl chloride, linoleum, cork and rubber. It details suitable methods of installation and advises on the selection of the materials required for their implementation. The guidelines in this Technical Specification are intended for use in cases where manufacturer's instructions, taking account of the national code of practice in the country where the installation is to be made, are not available. References to the national codes that are currently available are listed in the Bibliography of the various parts of this Technical Specification. This Technical Specification is intended for use in conjunction with CEN/TS 14472-1 that deals with general matters relevant to textile and laminate floor coverings as well as resilient floor coverings. It gives recommendations for the installation of resilient floor coverings in new or existing buildings. It describes common procedures which are in use throughout Europe and highlights the major differences that can exist in different national procedures. Special measures beyond those described in this Technical Specification may be necessary for the successful installation of resilient floor coverings for specialist purposes such as electrostatic control or use in special wet areas. These specialist techniques are not described in this Technical Specification.
Document Number:
NL EN TS 15398 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
35000.0000
This Technical Specification establishes a system of graphic symbols for use in the marking of the following floor coverings and specifies the use of these symbols: — resilient floor coverings manufactured from plastics, linoleum, cork or rubber, excluding loose-laid mats; — textile floor coverings, excluding loose-laid mats; — laminate floor coverings; — floor panels for floating installation.
Document Number:
NL 484 : 2016
Sector:
Petroleum and related Technologies
Status:
C
Production Year:
2016
Price:
25000.0000
تحدد هذه المواصفة المتطلبات القياسية وطرق الإختبار الخاصة بوقود الديزل لمحركات المركبات الآلية المعد للتسويق والتسليم. كما وتطبق هذه المواصفة على وقود الديزل للمحركات والمركبات الآلية المزودة بمحرك يعمل على الديزل ومصمم للتشغيل على وقود الديزل الذي لا يتخطى محتوى استر ميثيل الأحماض الدهنية فيه 7 % حجميا.
Document Number:
NL EN 179 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies requirements for the manufacture, performance and testing of emergency exit devices mechanically operated by either a lever handle or a push pad for the purpose of achieving a safe exit under an emergency situation on escape routes. The suitability of an emergency exit device for use on smoke/fire-resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard. Annex B indicates additional requirements for these products. This European Standard covers emergency exit devices, which are either manufactured and placed on the market in their entirety by one producer, or produced by more than one producer and subsequently placed on the market as a kit in a single transaction.
Document Number:
NL EN 671 1 : 2016
Sector:
Environment. Health protection. Safety
Status:
C
Production Year:
2016
Price:
25000.0000
This European Standard specifies requirements and methods of test for the construction and performance of fire hose reel systems with semi-rigid hose for installation in buildings, permanently connected to a water supply, for use by the occupants. It also provides requirements on evaluation of conformity and marking of these products. Its requirements may apply in general for other applications, for example in marine applications or in aggressive environments, but additional requirements can be necessary in such cases. This European Standard is applicable to both manual and automatic fire hose reels for installation with and without cabinets.
Document Number:
NL EN 671 2 : 2016
Sector:
Environment. Health protection. Safety
Status:
C
Production Year:
2016
Price:
35000.0000
This Standard specifies requirements for the manufacture, performance and testing of panic exit devices mechanically operated by either a horizontal push-bar or a horizontal touch-bar, specifically designed for use in a panic situation on escape routes. The suitability of a panic exit device for use on fire/smoke resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard. Annex B indicates additional requirements for these products. This Standard covers panic exit devices which are either manufactured and placed on the market in their entirety by one producer or produced by more than one producer and subsequently placed on the market as a kit in a single transaction.
Document Number:
NL EN 1125 : 2016
Sector:
Construction Materials and Building
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies requirements for the manufacture, performance and testing of panic exit devices mechanically operated by either a horizontal push-bar or a horizontal touch-bar, specifically designed for use in a panic situation on escape routes. The suitability of a panic exit device for use on fire/smoke resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard. Annex B indicates additional requirements for these products. This European Standard covers panic exit devices which are either manufactured and placed on the market in their entirety by one producer or produced by more than one producer and subsequently placed on the market as a kit in a single transaction.
Document Number:
NL EN 54 2 : 2016
Sector:
Environment. Health protection. Safety
Status:
C
Production Year:
2016
Price:
50000.0000
This standard specifies requirements, methods of test, and performance criteria for control and indicating equipment (see item B of figure 1 of EN 54-1) for usein fire detection and fire alarm systems installed in buildings.
Document Number:
NL EN 54 16 : 2016
Sector:
Environment. Health protection. Safety
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies requirements, methods of test and performance criteria for voice alarm control and indicating equipment for use in fire detection and fire alarm systems installed in buildings, where the alarm signal is in the form of tone(s) or voice message(s), or both. It also provides for the evaluation of conformity of the equipment to the requirements of this European Standard. NOTE The overall requirements of a voice alarm system, especially concerning audibility and intelligibility, are not covered in this part of EN 54. The manufacturer should consider requirements of an overall system that may affect the equipment design. Such system requirements may be specified in another part of EN 54, in national legislation, codes and standards or in contractual documents
Document Number:
NL EN 54 23 : 2016
Sector:
Environment. Health protection. Safety
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies the requirements, test methods and performance criteria for visual alarm devices in a fixed installation intended to signal a visual warning of a fire between the fire detection and fire alarm system and the occupants of a building. It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system. This European Standard specifies the evaluation of conformity and the marking of the visual alarm devices. This European Standard applies to visual alarm devices that rely on software for their operation and to those that do not. This European Standard applies only to pulsing or flashing visual alarm devices, for example xenon beacons or rotating beacons. Devices giving continuous light output are excluded from this European Standard. This European Standard is not intended to cover visual indicators, for example those on detectors or on the control and indicating equipment.
Document Number:
NL EN 54 24 : 2016
Sector:
Environment. Health protection. Safety
Status:
C
Production Year:
2016
Price:
50000.0000
This European Standard specifies requirements, test methods and performance criteria for loudspeakers intended to broadcast a warning of fire between a fire detection and fire alarm system and the occupants of a building. This European Standard specifies loudspeakers for two types of application environment: type A, generally for indoor use and type B, generally for outdoor use. This European Standard does not cover loudspeakers for special applications, for example loudspeaker for use in hazardous applications, if such applications require additional or other requirements or tests than those given in this European Standard. This European Standard is not intended to cover addressable loudspeakers, loudspeakers with active components. Voice alarm sounders are covered in EN 54-3:2001