المعايير

Lighting columns. Requirements for reinforced and prestressed concrete lighting columns

2010

رقم المستند: NL EN 40 4 : 2010
القطاع: Construction Materials and Building
TC: NL TC 59
ICS: 93.080.40
This document specifies requirements for reinforced and prestressed concrete lighting columns. It applies to columns not exceeding 20 m height for post top lanterns and columns with brackets not exceeding 18 m height for side entry lanterns. This document specifies: a) performance related to the essential requirement of resistance to horizontal (wind) loads, measured in accordance with EN 40-3; b) performance under vehicle impact (passive safety) in support of the Essential Requirement No. 4 Safety in use, measured in accordance with the corresponding test methods included in this document or available in separate European Standards.