Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure – Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Guidance for the assessment of conformity
2014
رقم المستند: NL CEN TS 1329 2 : 2014
القطاع: Construction Materials and Building
TC: NL TC 138
ICS: 23.040.01 - 91.140.80
This Technical Specification gives guidance for the assessment of conformity of materials (compounds/formulations), products and assemblies in accordance with EN 1329-1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of thirdparty certification procedures. NOTE 1 It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1]. NOTE 2 If third-party certification is involved, it is recommended that the certification body is accredited to EN 45011 [2], EN 45012 [3] or EN ISO/IEC 17021 [4], as applicable. NOTE 3 In order to help the reader, a basic test matrix is given in Annex A. In conjunction with EN 1329-1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended to be used for the following purposes: for soil and waste discharge systems (low and high temperature) inside buildings (application area code "B"); for soil and waste discharge systems (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD"). NOTE 4 This is reflected in the marking of products by "B" or "BD".